CKSC high voltage iron core series reactor
product description
CKSC type iron core high-voltage reactor is mainly used in 6KV~10LV power system in series with high-voltage capacitor bank, which can effectively suppress and absorb high-order harmonics, limit closing inrush current and operating overvoltage, protect capacitor bank, and improve system voltage waveform , improve the grid power factor.
Executive standard
●IEC 289-88 “Reactor”
●GB 10229-88 “Reactor}}
●JB5346-98 “Reactor”
●DL462-92 “Technical Conditions for Ordering Series Reactors for High Voltage Shunt Capacitors”
download Google
●Rated capacity of the reactor
●System rated voltage and frequency
●Reactor rated reactance or reactance rate
●Maximum working voltage of the reactor
●Rated current and maximum continuous current
●Motion and thermal stability current and duration
●Other special requirements
product model
Model Description
Technical Parameters
Features
The iron core is made of high-quality low-loss cold-rolled oriented silicon steel sheet, punched and sheared by a high-precision punching machine, with small burrs, uniform rules, and neat and beautiful laminations, ensuring the low-temperature rise and low-noise performance of the reactor during operation
The coil is epoxy casting type, and epoxy glass mesh cloth is laid inside and outside the coil for reinforcement. It adopts F-class epoxy casting system to cast in vacuum state. The coil not only has good insulation performance, but also has good mechanical strength and can withstand large Current shock and hot and cold shock without cracking.
●Epoxy casting coils do not absorb water, have low partial discharge, and can operate safely under severe environmental conditions.
●The upper and lower ends of the coil adopt epoxy pads and silicon rubber anti-vibration pads, which effectively reduce the vibration when the coil is running.
Other parameters
CKSC dry-type iron core series reactor series technical parameter table
Conditions of Use
●The altitude does not exceed 2000 meters
●Operating environment temperature -25°C~+45°C, relative humidity not more than 90%
●No harmful gas around, no flammable and explosive items
●The surrounding environment should have good ventilation conditions
Product Dimensions
Parameters required by the user when ordering
1. The rated capacity of the reactor
2. System rated voltage and frequency
3. Reactor rated reactance or reactance rate
4. Reactor high working voltage
5. Rated current and large continuous current
6. Dynamic and thermal stability current and duration